If you’ve ever stood outside a quiet, fenced substation on a crisp morning, watching power lines hum with the voltage that lights up your home or powers a local factory, you’ve probably wondered about the unsung workhorses inside that turn super-high voltage into something usable. As a substation supplier, I get asked this question all the time: how do those dry-type transformers tucked into substation corners actually work, especially when they’re chosen over their oil-filled cousins for everything from urban city centers to remote, wildfire-prone regions? I’ve spent the last 12 years designing, testing, and installing these units, so let me walk you through the process like I would to a new client or an engineer walking our shop floor for the first time. Substation

First, let’s start with the basics: what a transformer does, full stop. At its core, a transformer is a simple device that moves electrical power from one circuit to another by changing voltage levels—stepping high-voltage, low-current power from transmission lines down to low-voltage, high-current power that can run distribution lines to neighborhoods, or stepping up power from solar farms to send it across long distances. The key part here is that it doesn’t create power; it just transforms it, thanks to two invisible forces: electromagnetism and inductance. That’s true for every transformer, whether it’s sitting in a tiny green box on a sidewalk or inside a steel substation vault, and whether it’s filled with oil or air.
Which brings us to dry-type transformers, the ones I specialize in. Unlike oil-filled transformers, which use mineral oil as both an insulator and a coolant, dry types use air, nitrogen, or epoxy resin to do that job. That difference isn’t just a manufacturing detail—it changes where you can put them, how they perform, and how safe they are. Oil-filled units have to be housed in fire-resistant vaults or distant pads because a leak or fault can cause a fire, which is a huge risk in places like California or Colorado where wildfires are constant. Dry types? They can go almost anywhere: inside downtown office building basements, next to residential neighborhoods, even on the second floor of a new hospital wing without the same level of structural or fire safety hurdles. That’s why more and more municipalities and data centers are switching to them, and as a supplier, I’ve seen demand jump 40% in the last five years alone.
Now, let’s break down how they actually work, step by step. Let’s start with the building blocks. Every dry-type transformer has three main parts: two copper coils (called windings) wrapped around a laminated core made of silicon steel, and an insulating medium that fills the space around the core and windings. The core is what makes the magic happen—silicon steel is great at conducting magnetic flux, so it minimizes energy waste from stray magnetic fields. We laminate it (stack thin steel sheets with a thin insulating layer between them) to stop eddy currents, which are tiny, unwanted electrical currents that would make the core heat up and waste power. That’s a trick we’ve used for over a century, but it’s even more critical for dry types because they don’t have oil to carry away extra heat.
The windings are where the voltage change happens. There’s a primary winding, which connects to the incoming power line, and a secondary winding, which connects to the outgoing line. If you want to step voltage down from, say, 11,000 volts (a typical substation distribution voltage) to 480 volts (what runs factory equipment), the secondary winding will have fewer turns of copper wire than the primary. That ratio—number of turns on primary over number on secondary—directly matches the ratio of voltages: 11,000 divided by 480 is roughly 22.9, so the primary has 23 times more turns than the secondary. That’s Ohm’s Law in action, but with magnetism thrown in.
Here’s where the electromagnetism kicks in. When AC (alternating current) flows through the primary winding, it creates a constantly changing magnetic field around the core. That changing magnetic field cuts through the secondary winding, and because of Faraday’s Law of Induction, it pushes electrons through the secondary wire, creating a new current at the lower (or higher) voltage. The key here is that the power in stays almost equal to the power out—minus a tiny bit lost to heat in the core and windings. That’s why transformer efficiency is so high, usually 98% or better for units rated 500 kVA and up.
Now, the part that makes this “dry” instead of oil-filled: the insulation and cooling. Most modern dry-type transformers use epoxy resin to coat the windings, or they’re ventilated with ambient air, or sometimes pressurized with dry nitrogen. Epoxy-coated units are the most common in substations because they’re super durable—they resist dust, moisture, and even small sparks from lightning or equipment faults. When we coat the windings, we do it in a temperature-controlled vacuum chamber to make sure there are no air bubbles trapped, which would create weak spots that can break down under high voltage. That vacuum casting process is something we perfected at our factory last year; it cuts dielectric losses by 15% and makes the unit 20% more resistant to humidity, which is a big deal for substations in humid coastal areas like Florida or Louisiana.
Cooling is the other big difference between dry and oil transformers. Oil is an excellent coolant because it’s dense and carries heat away efficiently, but dry types rely on air flow. There are two main cooling classes for dry substation transformers: AN Class (air natural, AN) and AF Class (air forced, AF). AN Class units are cooled by natural convection—warm air rises out of the transformer, and cool air pulls in from the bottom of the unit. These are good for smaller loads, like substation feeders for a small neighborhood. AF Class units have fans that blow air across the windings and core, which lets them handle heavier loads, like feeding a hospital or a large retail complex. We’ve also developed a hybrid system for extreme climates—if a substation is in a place that gets very cold in winter, we add small heating elements to prevent condensation when the unit is idling, and in summer, we upgrade the fans to variable speed that adjusts based on the load. That’s a feature that our competitors often skip, but we’ve had clients in Minnesota tell us it cut their unplanned outages by 70% last year.
Wait, let’s talk about the real-world work of a dry-type transformer in a substation, because all the theory is nice, but what does that look like on a busy substation floor? Let’s take a 2,500 kVA dry-type unit we installed at a substation in Phoenix last year. The incoming power is a 69 kV transmission line from a solar farm 20 miles west of the city. The primary winding connects to that line, and the secondary steps it down to 12.47 kV, which feeds three distribution lines that serve 12,000 homes in northern Phoenix. On a hot summer day, when everyone is running AC, the load on that transformer jumps to 85% of its rated capacity. The AF Class fans kick on automatically, blowing air at 1,200 cubic feet per minute across the epoxy-coated windings. The core temperature stays at 122 degrees Fahrenheit, which is well under the maximum 150 degree limit, even when the outside air is 110 degrees. Because there’s no oil, we don’t have to install a 5,000-gallon oil containment pit, which saved the city $120,000 in construction costs for that substation. That’s the real value of dry-type units, not just the engineering, but the on-site savings and safety.
I get that some engineers still lean toward oil-filled transformers for very large substation projects, the ones over 10 MVA. That makes sense—oil can handle higher loads with smaller physical size, at a lower upfront cost. But for mid-sized substations, urban substations, or projects in areas with strict environmental regulations, dry-type is the clear choice. Another big advantage is maintenance: oil-filled units need oil testing every three to five years to check for moisture or contaminants, and they need to replace gaskets to prevent leaks. Dry-type transformers? We recommend an inspection every five to seven years, and the only maintenance is wiping dust off the cooling grates. That’s a huge win for utility companies that have limited maintenance crews. I had a client in Denver tell us that since they switched all their new substation transformers to dry-type three years ago, they’ve cut maintenance costs by 55% and avoided two potential fire incidents where an oil-filled unit would have failed.
Of course, there are common myths about dry-type transformers that I have to bust every week. The first one is that they’re less efficient than oil-filled. A properly engineered dry-type unit has almost the same efficiency as an oil-filled one—our 2,500 kVA Phoenix unit has a 98.7% efficiency rating, which is identical to the oil-filled units we quote for similar loads. The second myth is that they can’t handle heavy loads. That’s just not true—with the forced-air cooling option, a dry-type transformer can handle 150% of its rated capacity for short periods, which is more than enough for the peak loads that happen during heatwaves or holiday weekends. The third myth is that they’re more expensive. Upfront, they might cost 10 to 15% more than an oil-filled unit, but when you factor in the cost of fire suppression systems, containment pits, maintenance, and environmental compliance, dry-type usually ends up being cheaper over a 20-year lifespan.
As a substation supplier, we don’t just sell transformers—we design them to fit the specific needs of each substation project. That means we work with utility engineers to calculate the exact load, voltage levels, environmental conditions, and local regulations before we even start building. Last year, we had a project for a substation on the coast of Maine, where salt air is a constant risk. We had to upgrade our standard epoxy coating to a salt-resistant grade, and add a sealed cooling system to keep salt out of the windings. That unit has been running for 18 months with zero issues, which is something the client couldn’t get from our competitors. We also offer remote monitoring for all our dry-type substation transformers—our IoT sensors track temperature, load, and insulation integrity 24/7, and send alerts if something starts to go wrong. That’s a feature that’s becoming standard for new substation projects, especially as utilities move toward predictive maintenance instead of reactive repairs.
Let’s circle back to that substation you pictured earlier. The dry-type transformer isn’t the tallest or most obvious piece of equipment in there—you’ll see the big transmission line breakers, the capacitor banks for power factor correction, the control cabinets for monitoring. But without that quiet, efficient dry-type unit, none of that equipment would work as intended. It’s the bridge between the high-voltage power that travels hundreds of miles and the low-voltage power that powers your daily life.

If you’re working on a new substation project, or looking to upgrade an existing one, and you’re trying to figure out whether a dry-type transformer is the right fit, we can help. Whether you’re a utility in a wildfire-prone area, an urban developer needing to fit a substation in a tight space, or a industrial client needing reliable power for a factory or data center, our team has the expertise to design, manufacture, and install a dry-type transformer that meets your exact needs. We don’t do one-size-fits-all units—every transformer we build is tested before it leaves our factory, and we offer long-term support for every unit we install.
Gas Insulated Switchgear If you’re ready to discuss your project, reach out to our team to schedule a consultation. We can walk through your requirements, share case studies from similar projects, and answer any questions you have about how dry-type transformers work, their benefits, and how they fit into your substation design.
References
- Electrical Construction & Maintenance. (2022). “Dry-Type vs. Oil-Filled Transformers: Which Is Right for Your Substation.”
- IEEE Standard C57.12.00. (2020). General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers.
- National Fire Protection Association (NFPA). (2021). “NFPA 70: National Electrical Code, Article 450.”
- Substation Engineering Magazine. (2023). “Trends in Dry-Type Transformer Design for Urban Substations.”
Deepwill International Technology Development (Jiangsu) Co., Ltd.
Deepwill International Technology Development (Jiangsu) Co., Ltd. is one of the most professional substation manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy substation for sale here from our factory. Contact us for OEM service.
Address: No. 3-3 muyang Road, Hanjiang Economic Development Zone, Yangzhou city, Jiangsu Province, China.
E-mail: deepwill@deep-will.com
WebSite: https://www.deyunelectric.com/